Factory
Default Settings for pcb A1:
S1,S2,S3 are
used for computer interface.
They have been
set up at the factory as follows.
Address = “A”
BAUD
= 9600
{}
message delimiters
Check Sum check byte returned
No
parity
RS485 mode
Ignore bad Checksum
No
CR or LF returned
Termination resistor not engaged
Therefore, 7 bit words.
S4-1 “Off”
for 1:2 operation.
S5-1: “Off”
for normally open fault inputs.
(closure for a fault)
S5-2: “Off”
ignore closure fault inputs.
S5-3: “On”
Monitor amplifier current levels for
faults.
Factory
Settings for pcb A3:
The DNL-5
assumes that all amplifiers draw
less than 325 mA.
Therefor all
Jumpers on A3 (The top analog pcb
above A1 (main pcb)) are positioned
accordingly.
Delta V set at
0.6 volts.
The “2.5V”
potentiometer settings were set with
a current draw of 240 mA.
|